1. Catalogues
  2. ETAP
  3. CANECO TCC

CANECO TCC
1 /2Pages

CANECO TCC

CANECO TCC
1 /2Pages

Extraits du catalogue

CANECO TCC-1

Caneco TCC (Time Current Curve) software provides an accurate diagnostic overview of electrical power supply continuity. Results are based on the overlap of tripping curves of the various electrical protection systems. Caneco TCC enables protection relays to be adjusted, in order to ensure that they are protecting the electrical equipment against thermal effects, overload and short-circuit so as to obtain optimum discrimination. HV & LV protection discrimination study on Time/Current graph Check the reliability of your HV & LV electrical installations with ease Caneco TCC allows you to study the selectivity of a complex HV and/or LV electrical network. It gives you a clear and well-argued answer to questions relating to the quality of private or public electrical power supplies. It will: properly set your protection devices in order to get optimum discrimination in two network configurations, take into account the worst case constraints for your hardware (cables, receivers, neutral point coil), make sure that the start up of transformers does not actuate your protection systems. Ensures compliance when renovating electrical installations by manually plotting the tripping curves, in case of old electrical devices, simulating other protection functions when not described in the databases (e.g: fuse curves, rotor locking, motor start up, etc.), overlapping and adjusting the new tripping curves’ protections. Comprehensive LV & HV manufacturers’ database (fuses, relays, circuit breakers, generic equipments, etc.) All protection relay setting adjustments are based on manufacturer characteristics Transformer magnetising Interactive tripping curve resulting from user adjustments Thermal constraint of cables Quickly produce a comprehensive analysis report with: print-outs that include the title page, folio list, diagram, etc., tripping curve graphs, protection adjustment sheets. Graphs and curves can be annotated, labels moved, and values displayed. TITLE PAGE FOLIO LIST SINGLE LINE DIAGRAM SHEET OF ADJUSTED VALUES TRIPPING CURVES GRAP

 Ouvrir le catalogue en page 1
CANECO TCC-2

Caneco TCC meets the requirements of protective device studies. It carries out the checking and optimization of low and high voltage networks in order to find the best co-ordinated solution. Caneco TCC enables you to: define the protection plan, insure logical discrimination requirements, visualize all the possible operating situations, analyse the link between the generator and the distributor’s network, print out the notebook with adjustment values, provide a comprehensive report relating to the quality and reliability of electrical power supplies. Who is it designed for? Electrical...

 Ouvrir le catalogue en page 2

Tous les catalogues et fiches techniques (PDF) ETAP

  1. CANECO HT

    4  Pages

  2. CANECO BIM

    4  Pages

  3. CANECO BT

    4  Pages

Catalogues archivés

  1. BIM

    2  Pages

* Les prix s'entendent hors taxe, hors frais de livraison, hors droits de douane, et ne comprennent pas l'ensemble des coûts supplémentaires liés aux options d'installation ou de mise en service. Les prix sont donnés à titre indicatif et peuvent évoluer en fonction des pays, des cours des matières premières et des taux de change.